Loading...
HomeMy WebLinkAboutResolution 2019-032 Adoption of Building Codes MARANA RESOLUTION NO. 2019-032 RELATING TO BUILDING SAFETY; DECLARING THE 2018 INTERNATIONAL BUILDING CODE (IBC), THE 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC), THE 2018 INTERNATIONAL PLUMBING CODE (IPC), THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), THE 2018 INTERNATIONAL MECHANICAL CODE (IMC), THE 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE (IPMC), THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC), THE 2017 NATIONAL ELECTRICAL CODE (NEC), THE 2018 INTERNATIONAL FIRE CODE (IFC), THE 2018 INTERNATIONAL FUEL GAS CODE (IFGC), AND THE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) AND THE LOCAL AMENDMENTS TO THE FOREGOING CODES ADOPTED BY MARANA ORDINANCE NO. 2019.011 AS A PUBLIC RECORD BE IT RESOLVED BY THE MAYOR AND COUNCIL OF THE TOWN OF MARANA, ARIZONA as follows: SECTION 1. The following codes adopted by Marana Ordinance No. 2019.011., three copies of which are on file in the office of the Town Clerk, are hereby declared to be public records and ordered to remain on file with the Town Clerk: A. The 2018 International Building Code (IBC) and the local amendments to it. B. The 2018 International Existing Building Code (IEBC) and the local amend- ments to it. C. The 2018 International Plumbing Code (IPC) and the local amendments to it. D. The 2018 International Residential Code (IRC) and the local amendments to it. E. The 2018 International Mechanical Code (IMC) and the local amendments to it. F. The 2018 International Property Maintenance Code (IPMC) and the local amendments to it. G. The 2018 International Energy Conservation Code (IECC) and the local amendments to it. H. The 2017 National Electrical code (NEC) and the local amendments to it. 1. The 2018 International Fire Code (IFC) and the local amendments to it. J. The 2018 International Fuel Gas Code (IFGC) and the local amendments to it. 270053.DOCX/7. Marana Resolution No.2019-032 - 1 - K. The 2018 International Swimming Pool and Spa Code (ISPSC) and the local amendments to it. SECTION 2. The local amendments to the codes described in Section 1 adopted by Marana Ordinance No. 2019.011, a copy of which are attached to and incorporated in this resolution as Exhibits A through K, and three copies of which are on file in the of- fice of the Town Clerk, are hereby declared to be public records and ordered to remain on file with the Town Clerk. PASSED AND ADOPTED BY THE MAYOR AND COUNCIL OF THE TOWN OF MARANA, ARIZONA, this 16th day of April, 2019. Mayor Ed Aonea ATTES APPR ED AS TO F RM: Cherry L. Vawson, Town Clerk Fra/41Cassidy, Town Attorney ' w Cc=rr� .ter. w MARANA AZ FS'fAB4_ISHF[) 1977 270053.DOCX/1 Marana Resolution No.2019-032 -2- EXHIBIT A TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Building Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 104.8 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 105.1.1 Annual permit. REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: Instead of an individual permit for each alteration to an already approved electrical, gas, mechanical or plumbing installation, the building official is authorized to issue an annual permit upon application theFefeF to any peFsen, eMPIOYiRg ORe oF more qualified tFadepersens in the building, struGtwFe 9F en the premises owned or opeFated by the appikant fer the pe . Subject to the following: 1. The applicant for the registered plant annual permit shall be an architect registered in the State of Arizona and who shall be directly responsible for compliance with this code with respect to all work that would otherwjse require a permit. 2. All new applications need to be accompanied by a complete set of plans of the affected areas of construction with the scope of work and operations section clearly outlined. Annual registered plant permits shall not be granted for buildings or facilities not currently operating under a valid certificate of occuoancv. 3. Fees for annual permits shall expire on December 31st of each year and will need to be renewed and approved for registered plant status to be maintained. 4. The permit will be suspended if the applicant becomes no longer employed by the registered plant. If this occurs,the plant will need to notify the Building Official and call for immediate inspection on any ongoing work until such time that a replacement registrant is approved by the Building Official, 5. Annual permits may be revoked at any time by the Building Official if the applicant fails to comply with requirements. 6. A summary report of all work done under the registered plant registration shall be prepared by the registered architect, and submitted annually to the Building Official. 7. Work conducted under the registered plant annual permit may be reviewed and inspected by the Building Official while the work is in progress or on an annual basis. 8. The following work is not to be covered within the scope of the annual permit and shall require separate permitting: a. Any work creating a different occupancy classification or group for any or all portion of a building. b. Any work creating a different building type for all or any portion of a building. c. Any work that adds. alters, removes or penetrates required firewalls or barriers,exit courts. exit passageways or horizontal exits. d. Any work that provides for the relocation of more than five sprinkler heads. e. Any work that modifies load-bearing structures. 00062680.DOCX/2 Section 105.2 Work exempt from permit(Building), REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: 1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided that the floor area is not greater than 4,18 200 square feet(34 18.6 m2). [Numbers 2-13 remain unchanged] 14. Any work performed by or at the direction of the United States of America or the State of Arizona. 15 Amusement devices or structures located on a site for no more than 30 calendar days. 16.Temporary tents or membrane structures, provided they're in compliance with chapter 31 of the International Fire Code. 17 Re-roofing of existing buildings with similar materials regardless of value. Section 105.2 Work exempt from permit(Electrical). REVISE with following ADDITIONS shown with double underlining following paragraph number 3: [Numbers 103 remain unchanged] 4. Power for amusement devices and carnival rides in place on a site for less than (30) calendar days. 5. Repair or replacement of fixed motors and transformers of the same type and rating in the same location. 6. Temporary decorative lighting. 7. Repair or replacement of current-carrying parts of any switch, conductor, control device, or over-current device of the required capacity in the same location. 8. Electrical wiring. devices. appliances, apparatus or equipment operating at less than 25 volts and not capable of supplying more than 50 volts of energy except lighting devices that must meet the requirements of the lighting code. Section 105.2 Work exempt from permit(Mechanical). REVISE item number 6 as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: 6. Replacement of Portable evaporative coolers with like coolers. Section 113 BOARD OF APPEALS. DELETE title "Board of Appeals" and REPLACE with "Appeals". DELETE subsections 113.1 through 113.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section 114.4 Violation penalties. REVISE this section by DELETING "prescribed by law" and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." Section 115.3 Unlawful continuance. REVISE this section by DELETING "prescribed by law" and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." 00062680.DOCX/2 Section 202 Definitions. Swimming Pool. REVISE with DELETIONS shown with stFikequts and ADDITIONS shown with double underlining: SWIMMING POOL.Any structure intended for swimming, recreational bathing or wading that contains water over-2418 inches (640457mm) deep.This includes in-ground, above-ground and on-ground pools; hot tubs; spas and fixed-in-place wading pools. Section 308.2 Institutional Group 1-1. REVISE section by DELETING 16 and REPLACING it with 10. Section 308.2.3 REVISE section by DELETING each 16 and REPLACING each with 10. Section 308.3.2 Five or fewer persons receiving medical care. DELETE this section in its entirety. Section 310.4.1 Care facilities within a dwelling. REVISE section by ADDING "that are capable of self- preservation"following"Care facilities for five or fewer persons". Section 310.5 Residential Group R-4. REVISE section by DELETING 16 and REPLACING it with 10. 00062680.DOCX/2 EXHIBIT B TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Existing Building Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 104.8 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 112 BOARD OF APPEALS. DELETE title "Board of Appeals" and REPLACE with "Appeals". DELETE subsections 112.1 through 112.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section 113.4 Violation penalties. REVISE this section by DELETING "prescribed by law" and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." Section 114.3 Unlawful continuance. REVISE this section by DELETING "prescribed by law"and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." 00062685.DOCX/2 EXHIBIT C TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Plumbing Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 103.4 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment 106.1.1 Annual permit. REVISE section as follows with DELETIONS shown with stFkeeuts and ADDITIONS shown with double underlining: Instead of an individual construction permit for each alteration to an already approved system or equipment or appliance installation,the code official is authorized to issue an annual permit upon application therefor to any person, tradespersens in the building, structure or on the p d or operated by the appliGant feF the permit.subject to the following: 1. The applicant for the registered plant annual permit shall be an architect registered in the State of Arizona and who shall be directly responsible for compliance with this code with respect to all work that would otherwise require a permit. 2. All new applications need to be accompanied by a complete set of plans of the affected areas of construction with the scope of work and operations section clearly outlined. Annual registered plant permits shall not be granted for buildings or facilities not currently operating under a valid certificate of occupancy. 3. Fees for annual permits shall expire on December 31st of each year and will need to be renewed and approved for registered plant status to be maintained. 4. The permit will be suspended if the applicant becomes no longer employed by the registered plant. If this occurs,the plant will need to notify the Building Official and call for immediate inspection on any on oing work until such time that a replacement registrant is approved by the Building Official. S. Annual permits may be revoked at any time by the Building Official if the applicant fails to comply with requirements. 6. A summary report of all work done under the registered plant registration shall be prepared by the registered architect, and submitted annually to the Building Official. 7. Work conducted under the registered plant annual permit may be reviewed and inspected by the Building Official while the work is in progress or on an annual basis. 8. The following work is not to be covered within the scope of the annual permit and shall require separate permitting: a. Any work creating a different occupancy classification or group for any or all portion of a building. b. Any work creating a different building type for all or any portion of a building. c. Any work that adds, alters, removes or penetrates required firewalls or barriers,exit courts, exit passageways or horizontal exits. 00062707.DOCX/2 d. Any work that provides for the relocation of more than five sprinkler heads. e. Any work that modifies load-bearing structures. Section 106.6.2 Fee schedule. DELETE section in its entirety and REPLACE with "The fees for plumbing work shall be in accordance with the Town of Marana Fee Schedule." 106.6.3 Fee refunds. REVISE by INSERTING 80% in both blanks that state "SPECIFY PERCENTAGE". Section 108.4 Violation penalties. REVISE section as follows with DELETIONS shown with stFikeeets and ADDITIONS shown with double underlining: Any person who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair plumbing work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be in violation , punishable by a fine of not Fnere than [AMOUNT-1 dollars or by imprisenment not exGeeding [NUMBER OF DAYS], or bath suGh fine and Each day that a violation continues after due net*r=e has been seFved shall be deemed a separate eff., Violation penalties are set forth in Marana Town Code Title 7.section 7-1- 5. Section 108.5 Stop work orders. REVISE section as follows with DELETIONS shown with r*r'�,r,eauTs and ADDITIONS shown with double underlining: Upon notice from the code official,work on any plumbing system that is being performed contrary to the provisions of this code or in a dangerous or unsafe manner shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to the owner's authorized agent, or to the person performing the work.The notice shall-state the conditions under which work is authorized to resume. Where an emergency exists, the code official shall not be required to give a written notice prior to stopping the work. Any person who shall continue any work on the system after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be in violation. liable for a fine of net less than [AMOUNT4 dellaFs 9F more than [AMOUNTI dell Violation penalties are set forth in Marana Town Code Title 7, section 7-1-5. Section 109 MEANS OF APPEAL. DELETE subsections 109.1 through 109.7 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section 305.4.1 Sewer depth. REVISE by INSERTING 12 in both blanks that state "NUMBER". Section 314.2.1 Condensate disposal. REVISE section by ADDING the following at the end of the paragraph: Condensate disposal shall be allowed to terminate as follows: 1. Into an approved fixture tailpiece, funnel drain, waste air gap fitting, floor sink, slop sink, and laundry tray. 2. At or below grade outside the building in an area capable of absorbing the condensate flow without surface drainage. 00062707.DOCX/2 3. Over roof drains or gutters or downspouts that connect to drainage pipes, provided they terminate at or above grade in an area capable of absorbing the condensate flow without surface drainage. Section 410.4 Substitution. REVISE section by ADDING a sentence to the end of the paragraph as follows: When a single drinking fountain is required, it may be substituted with a water dispenser. Section 903.1 Roof extension. REVISE by INSERTING 6 in blank that states"NUMBER". Section 1003.2 Approval. REVISE section as follows with DELETIONS shown with s*keguts and ADDITIONS shown with double underlining: The size, type and location of each interceptor and of each separator shall be designed and installed in accordance with the manufacturer's instructions and the requirements and the construction and design standards of the appropriate jurisdiction(s) providing sewage disposalof this section based an the aRtieipated eenditiens of use.Wastes that de nat require tFeatmeRt or separation shall not discharged inte any inteFeepter or separator. Section 1003 INTERCEPTORS AND SEPARATORS. REVISE by DELETING sections 1003.3 thru section 1003.10. 00062707.DOCX/2 EXHIBIT D TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Residential Code Section R101.1 Title. REVISE section by inserting Town of Marana Section R101.2 Scope. REVISE section as follows with DELETIONS shown with strikeouts Exception:The following shall be permitted to be constructed in accordance with this code where provided with a residential fire sprinkler system complying with Section P2904: 1. Live/work units located in townhouses and complying with the requirements of Section 419 of the International Building Code. 2. Owner-occupied lodging houses with five or fewer guestrooms. 3. A eare faGility with five er feweF persons FeeeiViRg eustedial care%vithim a &Nelling unit. 4. A GaFe faGility with five or fewer persons Feceiving Fnedieal eaFe vVithin a I-Avelling Unit. 15. A Gare faGility f9F five eF fewer persons FeGeiving care that aFe within a single family Wig. Section R102.5 Appendices. REVISE section as follows with DELETIONS shown with S+F'�crikeouts and ADDITIONS shown with double underlining: Provisions in the appendices "H" and "P" shall net apply; all others shall not. unless specif: Section R104.8 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section R105.2 Work Exempt from Permit(Building). REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: 7. Prefabricated swimming pools that are less than 2-418 inches (649 457 mm) deep. Section R105.2 Work Exempt from Permit(Mechanical). REVISE section as follows with DELETIONS shown with strikeeuts and ADDITIONS shown with double underlining: 6. Portable evaperative cool Replacement of evaporative coolers with like coolers. ADD new Section R106.6: Section 106.6 Model plans. When two or more buildings, structures, or systems of regulated equipment are to be built without substantial modifications as defined by the Building Official, an applicant may apply for a model plan permit.This permit shall be charged plan review fees with additional fees for each exterior design elevation.The Building Official shall determine the number and type of accepted revisions/options per model plan.The model plan shall be designed for a specific subdivision(s) and may be used in that subdivision(s)without being 00062688.DOCX/2 subject to renewal until that subdivision is built out. Models designed to be used in any location allowed by soil condition shall be valid only until the next code change as adopted by the Town. Section R112 BOARD OF APPEALS. DELETE title "Board of Appeals" and REPLACE with "Appeals". DELETE subsections 112.1 through 112.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section R113.4 Violation penalties. REVISE this section by DELETING "prescribed by law" and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." Section R114.3 Unlawful continuance. REVISE this section by DELETING "prescribed by law" and REPLACING with "set forth in Marana Town Code Title 7, section 7-1-5." Table R301.2(1)Climatic and Geographic Design Criteria, REVISE to state the following: TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND WINDDESIGN SEISMIC SUBJECTTO DAMAGE FROM WINTER ICE BARRIER AIR MEAN SNOWSpeed Topographic Special wind Windborne DESIGN Frost line DESIGN UNDERLAYMENT FREEZING ANNUAL LOAD (mph) Effects region debriszone CATEGOR Weathering depth Termite TEMP REQUIRED FLOOD HAZARD INDEX TEMP Contact Marana MODERATE Flood Plain 1500 or 0 115 NO NO NO B NEGLIGIBLE 0 TO HEAVY 32 NO Management less 68 MANUALJ DESIGN CRITERIA Heating Altitude correction Indoordesign temperature Elevation La"itude Winter Heating Summer Cooling factor temperature Design temperature cooling difference Cooling temperature Wind velocity Wind velocity difference heating cooling Coincident wet bulb Daily range Winterhumidity Summer humidity Section R313 Automatic Fire Sprinkler Systems. DELETE section in its entirety. Section M1411.3 Condensate disposal. REVISE section by ADDING the following at the end of the paragraph: Condensate disposal shall be allowed to terminate as follows: 1. Into an approved fixture tailpiece, funnel drain,waste air gap fitting,floorsink, and laundry way. 2. At or below grade outside the building in an area capable of absorbing the condensate flow without surface drainage. 3. Over roof drains,gutters, or downspouts that connect to drainage pipes,provided they terminate at or above grade in an area capable of absorbing the condensate flow without surface drainage. Section P2603.5.1 Sewer depth. Insert [number] as"12" in both locations. Section P2904.1.1 Required sprinkler locations. REVISE section by DELETING the first sentence and REPLACING with the following: "Sprinklers are not required within dwelling units.This section serves as a guide for voluntary installations or to allow for a Fire-Resistant Construction reduction within section R302." 00062688.DOCX/2 EXHIBIT E TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Mechanical Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 103.4 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 106.2 Permits not required. REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: 6. Replacement of Portable evaporative coolers with like coolers. Section 106.5.2 Fee schedule. DELETE section in its entirety and REPLACE with "The fees for mechanical work shall be in accordance with the Town of Marana Fee Schedule." 106.5.3 Fee refunds. REVISE by INSERTING 80% in both blanks that state "SPECIFY PERCENTAGE". Section 108.4 Violation penalties. REVISE section as follows with DELETIONS shown with s+F'its and ADDITIONS shown with double underlining: Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair mechanical work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be in violation , rneFe than [AMOUNT-1 dollars eF by imprisenment not e)(Geeding [NUMBER OF DAYSI, er beth suGh fine and improsenme-M. Far--h day that a vielation eontiRues a4er due netiGe has been served shall be deemed a separate . Violation penalties are set forth in Marana Town Code Title 7, section 7-1- 5. Section 108.5 Stop work orders. REVISE section as follows with DELETIONS shown with strikeewts and ADDITIONS shown with double underlining: Upon notice from the code official that mechanical work is being performed contrary to the provisions of this code or in a dangerous or unsafe manner, such work shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to the owner's authorized agent, or to the person doing the work.The notice shall state the conditions under which work is authorized to resume. Where an emergency exists, the code official shall not be required to give a written notice prior to stopping the work.Any person who shall continue any work on the system after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be in violation. liable for a fine ef not less than [AMOUNTj dollars or mere than {AMOUNT-dollars. Violation penalties are set forth in Marana Town Code Title 7, section 7-1-5. Section 109 MEANS OF APPEAL. DELETE subsections 109.1 through 109.7 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." 00062689.DOCX/2 Section 307.2.1 Condensate disposal. REVISE section by ADDING the following at the end of the paragraph: Condensate disposal shall be allowed to terminate as follows: 1. Into an approved fixture tailpiece, funnel drain,waste air gap fitting,floorsink, slop sink, and laundry tray. 2. At or below grade outside the building in an area capable of absorbingthe condensate flow without surface drainage. 3. Over roof drains or gutters or downspouts that connect to drainage pipes, provided they terminate at or above grade in an area capable of absorbing the condensate flow without surface drainage. Section 1004.1 Standards, REVISE section as follows with ADDITIONS shown with double underlining: 1004.1 Standards. Boilers shall be designed, constructed and certified in accordance with the ASME Boiler and Pressure Vessel Code, Section I or IV and Arizona Boiler Rules,Title 20,Chapter 5. Controls and safety devices for boilers with fuel input ratings of 12,500,000 Btu/hr(3,662,500 W) or less shall meet the requirements of ASME CSD-1. Controls and safety devices for boilers with inputs greater than 12,500,000 Btu/hr(3,662,500 W) shall meet the requirements of NFPA 85. Packaged oil-fired boilers shall be listed and labeled in accordance with UL 726. Packaged electric boilers shall be listed and labeled in accordance with UL 834. Solid-fuel-fired boilers shall be listed and labeled in accordance with UL 2523. 00062689.DOCX/2 EXHIBIT F TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Property Maintenance Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 103.4 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 103.5 Fees. REVISE by adding Town of Marana Fee Schedule Section 109.6 Hearing. REVISE by DELETING appeals board and REPLACING it with Board of Adjustment Section 111.1 Application for Appeal. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment. REVISE by DELETING 20 days and REPLACING it with 10 days Section 111. 2 Membership of board. REVISE by DELETING this section and its subsections in their entirety Section 111.3 Notice of meeting. REVISE by DELETING paragraph in its entirety and REPLACING it with "Within seven business days after receipt of the owner's, occupant's or lessee's request for appeal the town shall either withdraw or modify the notice or schedule an appeal hearing before the Board of Adjustment.The owner occupant or lessee shall be notified in writing by certified mail of the date, time and location of the hearing.The hearing shall be scheduled not less than 15 calendar days and no more than 30 calendar days after receipt by the town clerk of the request for hearing." Section 111.4 Open hearing. REVISE by DELETING Title "Open hearing" and REPLACING it with "Hearing." REVISE by DELETING remaining paragraph and subsections in their entirety and REPLACING them with "The hearing shall be conducted in an informal manner and the rules of evidence shall not apply. The owner occupant or lessee may be represented by an attorney.The Board of Adjustment may affirm or withdraw the notice or modify the scope of the work required by the notice.The decision of the Board of Adjustment is final." Section 111.7 Court review. REVISE by DELETING this section in its entirety. Section 111.8 Stays of enforcement. REVISE section by DELETING appeals board and REPLACING it with Board of Adjustment. Section 112.4 Failure to comply. Revise section by DELETING "of not less than (amount) dollars or more than (amount) dollars" and REPLACING with "that shall not exceed $1,000 unless otherwise designated in this code, a town ordinance or under state law." Section 202 General Definitions. REVISE Cost of Such Demolition or Emergency Repairs by DELETING board of appeals and REPLACING it with Board of Adjustment. Section 302.4 Weeds. REVISE by inserting 9 inches in height. 00062768.DOCX/1 Section 304.14 Insect Screens. REVISE section by DELETING "During the period from (date)to (date)" and CAPITALIZING "every." Section 602.3 Heat supply. REVISE section by DELETING "During the period from (date)to (date)to maintain" and REPLACING with "capable of maintaining." Section 602.4 Occupiable work spaces. REVISE section by DELETING "During the period from (date)to (date)to maintain" and REPLACING with "capable of maintaining." 00062768.DOCX/1 EXHIBIT G TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Energy Conservation Code Section C101.1 Title. REVISE section by inserting Town of Marana Section C109 BOARD OF APPEALS. DELETE subsections C109.1 through C109.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section C402.1.1 Low-energy buildings. REVISE section by ADDING item#4: 4. Structures not intended for public occupancy that have openings in the thermal envelope during business operations and do not utilize air conditioning such as repair garages, fabrication shops, warehouses, or similar facilities. Section C403.1.1 Calculations of heating and cooling loads. REVISE section by ADDING the following at the end of the paragraph: Not required for emergency replacement of cooling and heating equipment where there are no alterations, additions, or changes of occupancy, the equipment does not increase in capacity, and the equipment was installed prior to this code cycle. Section R101.1 Title. REVISE section by inserting Town of Marana Section R109 BOARD OF APPEALS. DELETE subsections R109.1 through R109.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section R403.10.3 Covers. DELETE this section in its entirety. 00062740.DOCX/2 EXHIBIT H TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2017 National Electrical Code Article 210.5 Identification for branch circuits. REVISE section by DELETING paragraph (C) and REPLACING it with the following: (C) Ungrounded conductors. Branch circuits shall conform to the following color code. Volts Phase System Phase A Phase B Phase C Grounded Conductor 120/208 3 WYE Black Red Blue White 277/480 3 WYE Brown Orange Yellow Grey 120/240 3 DELTA Black Orange Red White Exception No. 1:The above color-coding is not required in residential occupancies. Exception No. 2: Industrial occupancies holding a Registered Plant Permit may use their own coding system.The color coding system must be presented at the time of permit application for the Registered Plant Permit.The registrant must post the color code on the inside on the panel. Exception No. 3:Additions to an existing electrical system, where an alternate color-coding system exists.The alternate color coding system shall be continued. 00062741.DOCX/1 EXHIBIT I TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Fire Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 105.6 Required Operational Permits. REVISE section by DELETING language in 105.6 and all subsequent subsections(105.6.1 through 105.6.50)and REPLACE with: "Coordinate with local, responding fire district/department regarding the requirement of operational permits." Section 105.7.25 Temporary membrane structures and tents. REVISE section by DELETING 400 and REPLACING it with 700. REVISE by DELETING 37 and REPLACING it with 65. REVISE subsection 3.1 by DELETING 700 and REPLACING it with 900 and DELETING 65 and REPLACING it with 83. REVISE subsection 3.2 by DELETING 700 and REPLACING it with 900 and DELETING 65 and REPLACING it with 83. Section 109 BOARD OF APPEALS. DELETE title "Board of Appeals" and REPLACE with "Appeals". DELETE subsections 109.1 through 109.3 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." Section 110.4 Violation penalties. DELETE this section and REPLACE with "Violation penalties are set forth in Marana Town Code Title 7, section 7-1-5." Section 112.4 Failure to Comply. DELETE this section and REPLACE with "Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as set forth in Marana Town Code Title 7, section 7-1-5." Section 202 GENERAL DEFINITIONS. Occupancy Classification. REVISE definitions as follows with DELETIONS shown with strikeewts and ADDITIONS shown with double underlining: OCCUPANCY CLASSIFICATION. Institutional Group 1-1. Institutional Group 1-1 occupancy shall include buildings, structures or portions thereof for more than-16 10 persons, excluding staff,who reside on a 24-hour basis in a supervised environment and receive custodial care. Buildings of Group 1-1 shall be classified as one of the occupancy conditions indicated below. This group shall include, but not be limited to following: Alcohol and drug centers Assisted living facilities Congregate care facilities Group homes Halfway houses 270045.DOCX/2 Residential board and care facilities Residential board and custodial care facilities Social rehabilitation facilities [No changes to Condition 1] [No changes to Condition 2] Six to 3.610 persons receiving custodial care. A facility housing not fewer than six and not more than 46 10 persons receiving custodial care shall be classified as Group R-4. DELETE Five or fewer persons receiving custodial care section. Residential Group R-3. Congregate living facilities(nontransient) with X610 or fewer occupants Care facilities within a dwelling. Care facilities for five or fewer persons that are capable of self- preservation receiving care that are within a single-family dwelling are permitted to comply with the International Residential Code provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or with Section P2904 of the International Residential Code. Residential Group R-4. Residential Group R-4 shall include buildings, structures or portions thereof for more than five but not more than&610 persons that are capable of self-preservation, excluding staff, who reside on a 24-hour basis in a supervised residential environment and receive custodial care. Building of Group R-4 shall be classified as one of the occupancy conditions indicated below. This group shall include, but not be limited to,the following: [No changes to remainder of definition] Section 304.1.2 Vegetation. REVISE by DELETING "Vegetation clearance requirements in urban- wildland interface areas shall be in accordance with the International Wildland-Urban Interface Code." Section 307.3 Extinguishment authority. REVISE by INSERTING "responding fire district/department or Marana Police Department" after fire code official. SECTION 503 FIRE APPARATUS ROADS. REVISE section as follows with DELETIONS shown with str+kPeuts and ADDITIONS shown with double underlining: Section 503.2.3 Surface. Fire apparatus access roads shall be designed and maintained to support the imposed loads of fire apparatus, per Section D102.1,and shall be surfaced so as to provide all-weather driving capabilities. Section 503.6.1 Electric operating gates. Gates that use electric or other means of power to automatically open or unlock shall have a manual override system. Manual override controls shall be located on the entrance side of gate, or when power has failed. the gates(s) shall open and stay open until power is restored for normal operations. 270045.DOCX/2 Section 503.6.2 Fire apparatus access road gates. Gates/barricades securing the fire apparatus access roads shall comply with all of the following criteria: 1.The minimum gate width shall be 20 feet(6096mm) unobstructed. 2. Gates shall be of the swinging or sliding type. 3. Construction of gates shall be of materials that allow manual operation by one person. 4. Gate components shall be maintained in an operative condition at all times and replaced or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by the responding fire personnel for emergency access on to the property or leaving the property. 6. Locking device specifications shall be submitted for approval by the fire code official. 7. Gates/barricades that are permanently secured for access reasons shall be posted with the approved fire access signs, on both sides of the gate/barricade. Signs can be mounted ongate or follow requirements under Section D103.6. Section 503.7 Maintenance.The person(s) in possession of the premises, on and into which a fire apparatus access roadway is required, shall be solely responsible for the maintenance of such roadways and all required signs. No owner, manager or other persons) in charge of premises served by a reauired fire apparatus access roadway shall abandon or close the fire apparatus roadway or any part thereof without permission of the fire code official. The person(s) in possession of the premises shall be responsible for ensuring that fire apparatus roadways are clear at all times. SECTION 507 FIRE PROTECTION WATER SUPPLIES. REVISE section as follows with ADDITIONS shown with double underlining: Section 507.5.7 Reflective pavement markers. Fire hydrants shall be identified by the installation of approved blue reflective pavement markers. Section 510.1 Emergency responder radio coverage in new buildings. REVISE by DELETING "public safety communications system" and REPLACING with "Pima County Wireless Integrated Network (PCWIN)800 MHz Radio System utilized by the Northwest Fire District." Section 5608.10 Disposal. REVISE by DELETING 15 and REPLACING with 60. The following Appendix Requirements are ADOPTED: APPENDIX B: FIRE FLOW REQUIREMENTS FOR BUILDINGS APPENDIX C: FIRE HYDRANT LOCATIONS AND DISTRIBUTIONS APPENDIX D: FIRE APPARATUS ACCESS ROADS Section D103.6.2 Roads more than 26 feet in width. REVISE section as follows by ADDING: 270045.DOCX/2 Exception: Roads 32 feet or wider with wedge curbs on both sides(measured from end of curb to end of curb) are not required to be posted. 270045.DOCX/2 EXHIBIT J TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Fuel Gas Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 103.4 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 106.1.1 Annual permit. REVISE with DELETIONS shown with stri eUts and ADDITIONS shown with double underlining: 106.1.1 Annual permit. Instead of an individual construction permit for each alteration to an already approved system or equipment or appliance installation, the code official is authorized to issue an annual permit upon application therefor to any peFsen, permit. subiect to the following: 1. The applicant for the registered plant annual permit shall be an architect registered in the State of Arizona and who shall be directly responsible for compliance with this code with respect to all work that would otherwise require a permit. 2. All new applications need to be accompanied by a complete set of plans of the affected areas of construction with the scope of work and operations section clearly outlined. Annual registered plant permits shall not be granted for buildings or facilities not currently operating under a valid certificate of occupancy. 3. Fees for annual permits shall expire on December 31st of each year and will need to be renewed and approved for registered plant status to be maintained. 4. The permit will be suspended if the applicant becomes no longer employed by the registered plant. If this occurs,the plant will need to notify the Building Official and call for immediate inspection on any ongoing work until such time that a replacement registrant is approved by the Building Official. S. Annual permits may be revoked at any time by the Building Official if the applicant fails to comply with requirements. 6. A summary report of all work done under the registered plant registration shall be prepared by the registered architect, and submitted annually to the Building Official. 7. Work conducted under the registered plant annual permit may be reviewed and inspected by the Building Official while the work is in progress or on an annual-ba J5. 8. The following work is not to be covered within the scope of the annual permit and shall require separate permitting: a. Any work creating a different occupancy classification or group for any or all portion of a building. b. Any work creating a different building type for all or any ortion of a building. c. Any work that adds, alters, removes or penetrates required firewalls or barriers exit courts, exit passageways or horizontal exits. d. Any work that provides for the relocation of more than five sprinkler heads. e. Any work that modifies load-bearing structures. 00062698.DOCX/2 Section 106.6.2 Fee schedule, DELETE section in its entirety and REPLACE with "The fees for work shall be in accordance with the Town of Marana Fee Schedule." Section 106.6.3 Fee refunds. REVISE by INSERTING 80% in both blanks that state "SPECIFY PERCENTAGE". Section 108.4 Violation penalties. REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlinine: Persons who shall violate a provision of this code,fail to comply with any of the requirements thereof or erect, install, alter or repair work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be in violation guilty ef a [SPEEGIFY OFFENSE1, punishable by a fine of not mere than [AMOUNT-1 dollars eF by impFisenrneRt not e)(eeediRg [NUMBER OF DAYSI, or beth suGh fiRe and imprisenment. Each day that a rUentinues a4eF due notice has been served shall be deemed a separate offense. Violation penalties are set forth in Marana Town Code Title 7. section 7-1-5. Section 108.5 Stop work orders. REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: Upon notice from the code official that plumbing work is being performed contrary to the provisions of this code or in a dangerous or unsafe manner, such work shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to the owner's authorized agent, or to the person doing the work.The notice shall state the conditions under which work is authorized to resume. Where an emergency exists,the code official shall not be required to give a written notice prior to stopping the work.Any person who shall continue any work on the system after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be in violation. liable feF a fine ef not less than [AMOUNTI dellaFs OF mare than [AMOUNT-] dollars. Violation aenalties are set forth in Marana Town Code Title 7. section 7-1-5. Section 109 MEANS OF APPEAL. DELETE subsections 109.1 through 109.7 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." 00062698.DOCX/2 EXHIBIT K TO MARANA RESOLUTION No. 2019-032 Town of Marana Amendments to the 2018 International Swimming Pool and Spa Code Section 101.1 Title. REVISE section by inserting Town of Marana Section 103.4 Liability. REVISE section by DELETING board of appeals and REPLACING it with Board of Adjustment Section 105.6.2 Fee schedule. DELETE section in its entirety and REPLACE with "The fees for work shall be in accordance with the Town of Marana Fee Schedule." 105.6.3 Fee refunds. REVISE by INSERTING 80 in both blanks that state "SPECIFY PERCENTAGE". Section 107.4 Violation penalties. REVISE section as follows with DELETIONS shown with strikeouts and ADDITIONS shown with double underlining: Any person who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair a pool or spa in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be in violation , punishable by a fine of not meFe t [AMOUNTI dollars or by not exceeding [NUMBER OF DAVS1, or beth suGh fine and ^ffepse. Violation penalties are set forth in Marana Town Code Title 7. section 7-1-5. Section 107.5 Stop work orders. REVISE section as follows with DELETIONS shown with stFikeOUts and ADDITIONS shown with double underlining: Upon notice from the code official, work on any system that is being performed contrary to the provisions of this code or in a dangerous or unsafe manner hall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to the owner's authorized agent, or to the person performing the work.The notice shall state the conditions under which work is authorized to resume. Where an emergency exists,the code official shall not be required to give a written notice prior to stopping the work. Any person who shall continue any work on the system after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be in violation. liable for a fine ef net less than [AMOUNTI dollars eF more than [AMOUNT-1 dellars. Violation penalties are set forth in Marana Town Code Title 7, section 7-1�5. Section 108 MEANS OF APPEAL. DELETE subsections 108.1 through 108.7 and REPLACE with "The means of appeal are set forth in Marana Town Code Title 7, section 7-1-6." 301.1 Scope. REVISE section as follows with DELETIONS shown with +"*kPA-t-;:The provisions of this chapter shall govern the general design and construction of his and residential pools and spas and related piping, equipment, and materials. PFovisions that are unique to a spedfie type of pool or spa are located in Chapters 4 through 10. 00062717.DOCX/3 Section 301.1.1 Applications of Chapters 4 through 10. REVISE by REPLACING every 4 with a 7. Section 305.2.1 Barrier height and clearances. REVISE item 1 as follows with DELETIONS shown with str-ikeauts and ADDITIONS shown with double underlining: Barrier heights and clearances shall be in accordance with all of the following: 1. The top of the barrier shall be not less than 60 4R inches(1524 3219 mm) above grade where measured on the side of the barrier that faces away from the pool or spa.Such height shall exist around the entire perimeter of the barrier and for a distance of 3 feet (914 mm) measured horizontally from the outside of the required barrier. Chapter 4, DELETE in its entirety and reference the ARIZONA ADMINISTRATIVE CODE,TITLE 18, CHAPTER 5,ARTICLE 2. as applicable. Chapter 5, DELETE in its entirety and reference the ARIZONA ADMINISTRATIVE CODE,TITLE 18, CHAPTER 5,ARTICLE 2. as applicable. Chapter 6, DELETE in its entirety and reference the ARIZONA ADMINISTRATIVE CODE,TITLE 18, CHAPTER 5,ARTICLE 2. as applicable. 00062717.DOCX/3